- Видео 230
- Просмотров 1 565 276
abrelectric
Добавлен 7 июн 2014
Welcome to ABR Electric's RUclips Channel - The Electrical Experts of McKinney, TX, and Surrounding Areas in Collin County!
🔌 Dive into the world of ABR Electric, where we stand as Collin County's foremost electrical contractor and a recognized Generac dealer. Based in McKinney, TX, we extend our top-tier services to neighboring cities like Plano, Frisco, and Allen. Our channel showcases the expertise and dedication of our local electricians, ensuring you get insights straight from the professionals.
ABR Electric is an electrical contractor and a businesses that employ electricians to design, install, and maintain electrical systems in both commerical and residential. Our licensed team of electricians in McKinney, TX are dedicated to your satisfaction, living by our motto: "Do it right, create a positive memory, and have fun!. Reach out now for an appointment and a quote! Safely operating the main office at 1971 Univ Business Dr #106, McKinney, TX 75071. ABR Electric 214-690-1941
🔌 Dive into the world of ABR Electric, where we stand as Collin County's foremost electrical contractor and a recognized Generac dealer. Based in McKinney, TX, we extend our top-tier services to neighboring cities like Plano, Frisco, and Allen. Our channel showcases the expertise and dedication of our local electricians, ensuring you get insights straight from the professionals.
ABR Electric is an electrical contractor and a businesses that employ electricians to design, install, and maintain electrical systems in both commerical and residential. Our licensed team of electricians in McKinney, TX are dedicated to your satisfaction, living by our motto: "Do it right, create a positive memory, and have fun!. Reach out now for an appointment and a quote! Safely operating the main office at 1971 Univ Business Dr #106, McKinney, TX 75071. ABR Electric 214-690-1941
Amazon Low Profile Ceiling Fan Install!
At ABR Electric, we are dedicated to providing top-notch electrical services to our community. Our team of skilled and professional electricians is committed to ensuring the safety and satisfaction of our clients. One of our specialized services includes the installation of Amazon Low Profile Ceiling Fans.
🛠 Our Services Include: 🛠
Amazon Low Profile Ceiling Fan Installations 🌀: Perfect for rooms with lower ceilings, these fans provide efficient air circulation while maintaining a sleek, unobtrusive look. Our expert electricians ensure a seamless installation process, maximizing both functionality and aesthetic appeal.
Electrical Panel Replacements 📋: Upgrade your electrical system for optim...
🛠 Our Services Include: 🛠
Amazon Low Profile Ceiling Fan Installations 🌀: Perfect for rooms with lower ceilings, these fans provide efficient air circulation while maintaining a sleek, unobtrusive look. Our expert electricians ensure a seamless installation process, maximizing both functionality and aesthetic appeal.
Electrical Panel Replacements 📋: Upgrade your electrical system for optim...
Просмотров: 330
Видео
Energized Fence post shocking a child! What's going on? #GFCIpool #RAILprep #Mckinneyelectrician
Просмотров 120Месяц назад
Energized Fence post shocking a child! What's going on? #GFCIpool #RAILprep #Mckinneyelectrician
Installation of the The Vortexx™ Series R 1-Phase | ABR Electric of Plano
Просмотров 4903 месяца назад
Installation of the The Vortexx™ Series R 1-Phase | ABR Electric of Plano
Why Using Romex (NM) cable in Conduit Violates Electrical Codes
Просмотров 4,2 тыс.3 месяца назад
Why Using Romex (NM) cable in Conduit Violates Electrical Codes
Inside Look_ Vortexx™ Series R vs FS140 Siemens Surge Protectors
Просмотров 4233 месяца назад
Inside Look_ Vortexx™ Series R vs FS140 Siemens Surge Protectors
Testing Appliance Cord With a Meter
Просмотров 2,5 тыс.6 месяцев назад
Testing Appliance Cord With a Meter
Bad Vibes in the Kitchen: Kitchen Remodeling and Electrical Safety - The Kitchen of Death
Просмотров 1906 месяцев назад
Bad Vibes in the Kitchen: Kitchen Remodeling and Electrical Safety - The Kitchen of Death
Wash, Shock, and Repeat: When Noodling Around Goes Wrong
Просмотров 1956 месяцев назад
Wash, Shock, and Repeat: When Noodling Around Goes Wrong
Is the Texas Residential Appliance Installer test TOUGH? 🤔🔧📚
Просмотров 9 тыс.8 месяцев назад
Is the Texas Residential Appliance Installer test TOUGH? 🤔🔧📚
ABR Electric: McKinney's Premier Generac Dealer | Reliable Home Standby Power Solutions
Просмотров 1748 месяцев назад
ABR Electric: McKinney's Premier Generac Dealer | Reliable Home Standby Power Solutions
Don't Go Chasing Waterfalls The Real Deal on Layered Surge Protection with James Adams
Просмотров 4949 месяцев назад
Don't Go Chasing Waterfalls The Real Deal on Layered Surge Protection with James Adams
NFPA 70's National Electrical Code vs. Everyday Home Electrical Needs
Просмотров 1,5 тыс.9 месяцев назад
NFPA 70's National Electrical Code vs. Everyday Home Electrical Needs
3 Way Touch Sensor Dimmer, Touch Lamp Repair Kit Control Module
Просмотров 8 тыс.9 месяцев назад
3 Way Touch Sensor Dimmer, Touch Lamp Repair Kit Control Module
Planning for a 240 Volt Circuit Installation at Home
Просмотров 1,2 тыс.10 месяцев назад
Planning for a 240 Volt Circuit Installation at Home
Harmonic Distortion- Not Just Heavy Metal
Просмотров 27710 месяцев назад
Harmonic Distortion- Not Just Heavy Metal
Why Romex Doesn't Belong in Conduit: Quality and Longevity
Просмотров 53 тыс.11 месяцев назад
Why Romex Doesn't Belong in Conduit: Quality and Longevity
The Grounding Chronicles, An Epic Tale of Rods Texas Electrical Code 2020
Просмотров 98211 месяцев назад
The Grounding Chronicles, An Epic Tale of Rods Texas Electrical Code 2020
Rabbit Hole Training: Electrician Skills
Просмотров 147Год назад
Rabbit Hole Training: Electrician Skills
Attention All Aspiring Electricians. We need Your Input
Просмотров 82Год назад
Attention All Aspiring Electricians. We need Your Input
Sanity Saving Hacks Part 2 Residential Electrician: ABR Electric
Просмотров 449Год назад
Sanity Saving Hacks Part 2 Residential Electrician: ABR Electric
Electrician Hacks and Tricks: ABR Electric
Просмотров 989Год назад
Electrician Hacks and Tricks: ABR Electric
Let's do the Twist!: Reducing Inductance In Wire Leads for your Siemens FS140
Просмотров 3 тыс.Год назад
Let's do the Twist!: Reducing Inductance In Wire Leads for your Siemens FS140
"DO NOT TRY THIS: What Happens When You Dunk a Blow Dryer in a Bucket of Water? Shocking Results?!"
Просмотров 899Год назад
"DO NOT TRY THIS: What Happens When You Dunk a Blow Dryer in a Bucket of Water? Shocking Results?!"
Can You Run Southwire Romex NM-B Cable in Conduit Without Sheath?
Просмотров 12 тыс.Год назад
Can You Run Southwire Romex NM-B Cable in Conduit Without Sheath?
Surviving Supply Chain Disruptions: The Breaker Shortage & Zombie Waves Saga
Просмотров 912Год назад
Surviving Supply Chain Disruptions: The Breaker Shortage & Zombie Waves Saga
Why Bother with Smart Management Modules (SMMs) for Generac Standby Generators?
Просмотров 17 тыс.Год назад
Why Bother with Smart Management Modules (SMMs) for Generac Standby Generators?
Ok how in the hell do you run a new line through an attic to an air-conditioner the line has to come out of an eve theres no way to transition from romex to single strand without one touching the wrong area.
NM cant be run in damp/wet locations. Conduit is irrelevant. Inside its fine, even required in certain situations.
Unless you have a rat problem, but then there's always BX.
@bobmcgehee1749 true.
should I run Romex to a cealing fan through a conduit?
@paulchristopherriley7503 is this in a house with an attic or do you have to run the romex on the surface?
@@abrelectric the romex can run through the attic. thanks
Nice repair. I come across garbage like this much too often and I usually fix it just like this with a medallion to cover up the imperfection.
@@electricalron thank you!
You are totally awesome!!! I am a 75 year old widow who knows zero about things electric. You solved my problem without an electrician. So happy. God bless!
@@helenmcbroom thank you for sharing the happy outcome!
The weight of this fan, not sure why it would need to be a fan rated box
@divemanred future installations, could be anything. And, the Code thing
@@abrelectricwhat does the “code” define a fan? Is there and weight parameters?
@divemanred the current Code requires a ceiling outlet that "may" be used for a fan in the future, the outlet has to be fan rated
Wow, just WOW! As someone who will tackle simple tasks like replacing a worn out switch or outlet, I hesitate to go above that level of wiring for obvious reasons. From a DIY's standpoint I am certain that there is NO difference between the NEC and the bible. In both cases there is one book, many sects and 500 interpretations of what it means. How long until various factions band together, create their flags and meet on the battle field? The only uncertainty is the location of holy sites where battles can take place and/or miracles happen? Tesla's grave site? Wardencliff NJ perhaps? We all know that Edison was a false prophet by stealing inventions and killing elephants. Westinghouse followed Tesla so....... My guess is that sometime in the future an apprentice will have a revelation and wake up one morning after Tesla spoke to him or her in a dream with a complete understanding of the entire NEC? When this person attempts to spread the one and only correct way of completing every task though, a group of non-agreer's will crucify them on an electric pole with a MET-ED transformer? The true believers will carry on though, and hopefully have spread enough gospel to one day make the service panel a better place to work? Where or who is this messiah? The world needs them now!
I have a Stab Loc and the double 50 Amp breaker to the stove continuously comes loose and the stove cuts off while cooking. I have to go to the basement to wiggle it to come back on. Will a new breaker fix this or do I need a whole new box?
@frederick4367 A new after-market FPE may grip the bussing better. FPE also relies heavily on the deadfront to be tight to hold the breaker in place. I recommend you research the cost and replace the panel and breakers. Having to run to the basement to fiddle with a chronically loose breaker, in order to cook is unsafe and inconvenient.
NEC SAYS SPDS MUST HAVE A NOMINAL DISCHARGE CURRENT RATING OF NOT LESS THAN 10KA ART 215.18 E
@voltmanip Thank you. Do one of these units have a discharge rating less than 10KA? They're marked for 20KA.
Pull the meter. Like they always have done for house fires.
Is the fan UL listed? Also is the ground screw on the bracket necessary if the box is grounded and the fan ground is attached to the EGC? Isn't that redundant at that point just wondering as I was under the impression it was unnecessary in this case and if not I better start wrapping them up too.
Not UL listed. I think as long as the bracket was tight against the fan box, the EGC should cover it; I'm used to seeing those grd screws :)
@@abrelectric It definitely won't hurt to hook it up and with the medallion and unknown fan probably the right call. i work by myself for a while now so I like watching these vids to see what others are doing so thanks!
Why 60A wired when max charging is 48A? Shouldn't it be wired for 50A be better?
48 amps plus 25% for continuous load = 60 amps. Also per manufacturer's instructions.
You completely blew off two limitations. Manufacturers recommendations and pull resistant. If you don’t understand what I’m talking about then take this video down. The pull resistance issue is serious enough that every jurisdiction I’ve worked in specifically prohibits your crazy idea
Which crazy idea specifically? Since I'm not familiar with every jurisdiction, let's stick to the NEC. Please reference the NEC.
I run the generator the 1st day of every month
No cable to the faceplate that I’m able to find. Weird
This, as all the others have commented, was really helpful! I also learned about the Intermatic smart guard from you. So thank you for your content. I’d love to hear your updated thoughts on the Intermatic products, given it’s been about 3yrs since this video posted and maybe more importantly because Intermatic now has the 2280 line. (Apologies if you’ve already covered this but I somehow missed it but also thank you in advance!)
THE GAP is what youre seeing there???? That whole section of the roof is floating.
Neat, right? 😢
Does this apply to Commercial or Industrial?
Article 210.8 applies to both. Please review that section. The question always comes down to the Location by Code definition.
Would honestly like to know how you got romex out the wall. Did not think a 2x4 wall would give allow for bend radius particularly for 4awg.
I know what you mean. But it does work.
I'd never run Romex in EMT or Liquid Tight. I always runTHHN. Thanks
Thank you
What about furnace drops, basment wall receipts, etc.? Do you run complete conduit runs, or J-boxes at every drop point. Doesn't seem cost affective and your adding an unnecessary splice on the circuit. Not saying its a bad way to do it, maybe a little overkill.
@@ericnortan9012 BX is what's used for furnace and outlets.
Love seeing it come together 🎉
Thank you! Posted another progress video today
Thank you sooooo much! This worked brilliantly!
Fantastic! Please like and subscribe
Sorry I'm missing something... Why does it appear that the neutral and ground are on the same bus? Also, why are you adding a breaker to switch the surge protector?
It's a main panel, normally where neutrals and grounds are bonded together. The FS140 is a type 2 spd and requires a breaker. So, maybe you're missing something
You are missing something: the main panel has bussing with neutrals and grounds bonded together (not a subpanel). The FS140 is a Type 2 SPD and requires over current protection.
my first thought was bond good job dong forget gfci best wishes!! make sure the hvac a holes dont block your working clearances at final haha always good to see a post!
I thought the FS140 could be installed directly to the bus and not require a breaker?
Per the instructions it's a Type 2, needs a breaker.
Glad to see that paint ground off the building steel. Working in IT, I see my powder coated server racks left ungrounded or just attached to painted metal almost every time.
I can’t thank you enough for posting this video ! Saved me the time, trouble, and cost of calling an electrician ! 🎉❤
Thank you! Please subscribe- more tips here :)
Tell you what. In November 2023, I installed an FS140 to my new electrical service panel. The cost was just under $225 for the protector, I am happy about that. Not even a year later, they are selling for almost $450. I found an SFPD140 online for less than $100 currently. I am considering ordering that as a back up to install if the FS140 should fail. Just thought I'd pass on this tidbit of information if anyone was curious. Cheers.
The prices have gone crazy. Please also look at the PSP Vortexx. Similar specs. Pricing reasonable.
Good video. I just found this. I went through this a few years ago and waffled between the portable and permanent for a while. Finally I was about to pull the trigger on a 24kw permanent installation and looked things like consumption, maintenance and how much energy I actually consume. They are, as you say a pig! I'm all electric but have a 120gallon propane tank that runs a space heater. That 24kw unit would drain that tank in no time. And the only time I need 24kw is to start the heat pump. Most of the time I'm only using a few kw. Another issue with the permanent is even if you do all the maintenance what happens if it drops a valve or burns out a bearing ? You can't go down to NAPA (not a sponsor) to get a replacement. And all the maintenance/repair is at the unit, in the 'elements' ... during an ice storm, a heatwave, or a flood. Or even at your leisure grovelling around on the ground. If you want that 'turn-key' automatic operation many of us want (and that is not a bad thing) you need to see what kind of support (ongoing maintenance and repair agreements, turnaround, spare parts availability etc). My electrician said they install permanent generators but they don't maintain them. In the end I had the electrician install a 50amp generator inlet and a sub-panel feeding specific circuits (with an interlocking device). A 10kw portable generator that I run off propane cylinders (long story but the propane people out where I am don't like generator people lol). If the portable generator croaks I can wheel in another one. Of course that was two years ago and the last outage (after a winter storm) was over 3.
This guy is typical car sales mentality. He is full of it.
What a bunch of bull shit. FP panels are safe if installed properly and the bolts that hold the cover on are securely screwed in. The problem arises when there is insufficient pressure from the cover to hold the CBs pin against the buss bar. This can cause arcing creating temperatures as hot as the sun. The heat builds up inside the CB and melts or deforms the casing which can keep the CB from tripping. The CPSC investigated FP in 1983. Here is their findings. "The Consumer Product Safety Commission announced today that it is closing its two year investigation into Federal Pacific Electric Stab-lok type residential circuit breakers. This action was taken because the data currently available to the Commission does not establish that the circuit breakers pose a serious risk of injury to consumers." Nuf said.
Nope. My concern is the 2x in person, I have seen a dead short - across hots and ground - and the FPE breaker did not trip.
I guess your busy and not checking comments. I am trying to buy one.
Hi , I cant seem to get anyone here to sell me a unit. The company doesn't sell to consumers. Can you help?
FS140 or Vortexx?
@@abrelectric vortex all the way. Wanna tell all my neighbors about it as well.
@@pinballguru do you need a flush kit?
I can send you the Vortexx series R for $150 and a flush mount plate for $45. Shipping will add about $15.
@@abrelectric I am in Mckinney, I could come get it from you. It will go on the side of the unit so I think no on the flush kit. Thanks for helping. Do I need to text for payment etcetc.
That was an awesome video. Thank you. It
This is not completely correct especially the part about the interlock = lockout
I am finding the FA140 $200 more than the FSPD140 - Where are you getting your prices?
You should be minimizing the length between the surge protector and the panel. Ideally you want to mount it into a CB at the first position from where the L1/L2 Enters. Shorter length = better protection.
What are the dry contact #18 wires for on the fspd?
To operate a remote relay, i.e. maybe for a strobe light, bell, etc
So at 7:30, 24" lead with twist yields 600v. Not 36", but 24" is great for side mounting. I am playing wackamole on other electrician spd conversations, where this issue is posed but not resolved. I refer people to here.
I love this Vortexx R single phase. Not all of their R and Hurricane spd's have thermal protection, look for TFMOV in specs. The double tap, for Type 1 line side connection, is supposed to be made with the spade under the conductor, docu says. Weird, yes. I collected different 1/4"-20 thread options to use on bus studs, one option being thin jam nuts, another being threaded rod connectors and a hex screw. I looked at Harley faring standoffs, similar idea. Also looked at non-crimp non-toothy set screw connectors, some insulated, but those connect directly to feeder...a commenter posited using toothy screw down on feeder, no way that here.
Natural gas is not volatile enough to start a cold engine a portable generator is your best bet.
Nice looking solution to a tough mounting.
I love how you put the photo on the end for your your spectrum and OCD folks... but then only used one Tapcon. *Evil Laugh*
You saw that, did you? :)
So do I need to remove the yellow/gray protective jacket to run 6/3 wire in liquid tight conduit for a portable generator I’m using as a back-up generator for my house?
With UF no. If by "yellow " you mean NM cable or romex, use something outdoor rated
That is awesome from scratch!....I have one that is a manufactured one now for 2 years, worked fine and all, 3 way touch...but now, it won't stay off for any length of time. So when I do dissect it, what might I be looking for first?
I would replace the entire sensor. Unfortunately, there's not much to repair. Maybe, the ground connection inside is loose?
@@abrelectric Thanks so much, will keep you informed!
Can you run a bare ground from a 200 Amp box to a 100 Amp breaker box the wire will be run in a gray pvc conduit
#8 or larger in a raceway should be stranded. Article 310.3
⚡
I am planning for a 24000 BTU Mini Split in Texas. 240v 30amp I have room in the breaker box. Based upon another of your videos, I can run 10/2 NM romex from breaker and transition to J-box with #10 wires thru conduit for the outside run to a disconnect. Or Can I run 10/2 UF-B from the breaker box thru the attic and transition to 3/4" conduit for the outside run to a disconnect? 100 ' of UF-B wire roll is $137 at Lowes. Romex NM is $188.
Either will work. I'm not a fan of UF - just the makeup with the sheath.